EPO-AC
Integrated DX module (evaporator, condenser and compressor) on the device, fully automated, package design that does not need an outdoor unit.
Descriptions
Features
Options
Integrated DX module (evaporator, condenser and compressor) on the device, fully automated, package design that does not need an outdoor unit.
Exhaust and Supply Air Fans
The fans in packaged type energy recovery units with heat pump are equipped with innovative Electronically Commutated EC motor technology. EC motors have higher efficiency and simple speed control. Fan blades have high aerodynamic efficient backward curved design. EC motors reduce the energy consumption and increase the energy efficiency of the unit. With EC Fans, maintenance costs are reduced as the fans are directly connected to the motors; the belt and pulley problems are eliminated.Exhaust and Supply Air Filters
EPOVENT AC series packaged type heat recovery units with heat pump have standard ISO Course % 45 class pre-filters for both exhaust and supply air streams. A choice of ePM10 ≥ % 50 class final filters can be prefered optionally. ISO Course % 45 class pre-filters are washable and secured in rigid frames made of galvanized steel. ePM10 ≥ % 50 class final filters are innovative compact filters with increased filtration surface area to reduce initial pressure drop over the filter and also reduce size of units. All the filters comply with ISO 16890 to meet the requirements of odor absorption and dust arrestment. Fouled filter information is indicated in the control panel by standard installed differential pressure switches however pressure transmitter is also available optionally to observe fouling. Filter sections are designed to ease filter service and changing.Casing & Insulation
The unit’s casing is made up of double skinned high corrosion resistive 200 gr/m² galvanize coated steel. 50 mm thickness and 70kg/m³ density of Rockwool insulation between the walls is used for thermal and sound insulation. The case of unit is painted by electrostatic powdered paint. The unit is constructed in sections to ease transportation, mounting and commissioning. Every section has its own basis and transport slots.Heat Recovery Exchanger (Aluminum)
EPOVENT AC series packaged type heat recovery units with heat pump have high efficient aluminum crossflow, plate heat recovery exchangers with Eurovent certification.Compressor and Heat Pump Cycle
Units are equipped with a microprocessor based control system to meet various design needs. Both electrically and electronically control hardware comes with the unit that’s why the unit is “Plug and Play”. Exchanger monitoring and speed control, filter monitoring, fan monitoring are standard. With the use of optional IAQ, CO2 sensor or constant flow kit, fans regulate automatically according to user demand. Room control panel is supplied where no BMS protocol is demanded. The panel is BMS compatible and can handle various communication protocols like Modbus, Bacnet and Lonworks. Control System is also capable of controlling heating/cooling capacity when units are used with heating/cooling coils.Control System
High efficiency, fully hermetic compressors are used in the packaged type heat recovery units with heat pump. Externally balanced thermostatic expansion valve is used in the unit. The system safety is ensured with low and high pressure pressurestats. The system can work in heating or cooling mode depending on the season selection on the control panel.Evaporator & Condenser
Copper tube-aluminum fin type and high efficient evaporator and condenser are used. At the inlet of the evaporator, refrigerant distrubitor is used for a uniform distrubition. Since air velocity is selected as possible lower value for evaporator and condenser, as a result pressure drop on air side is reduced. There is a stainless steel drain pan under the evaporator and condenser. Also, siphon is given with the unit as standard.- Plate Type Heat Pump Integrated Air Handling Unit
- Production in three different types of high quality standard up to 28.000 m3 / h, fully automated
- Plate Heat Exchanger
- Low energy consumption and with AC or EC Plug Fan,
- Low noise level
- ISO COARSE >90%/ISO ePM 1 >50-65%
- Advanced, integrated automation system,
- Mod-Bus / BacNet alternatives
- Remote monitoring
- High mechanical performance values according to EN 1886, T2, TB2, D1, L1
- Specially designed casing,double skin isolated with rock wool ; 50 mm thick,and density of 70 kg / m3
- Screw adjustable feet,
- Eurovent certified selection software
- Special design, integrated into unit body, MCC-DDC panel
- Halogen-free jackets include in-device cabling, plug-in connectors for cell separations,
- Mechanical and electrical tests carried out 100% before shipmen
- Proportional By-Pass Damper Control
- On/Off Mix Damper Control
- Proportional Mix Damper Control
- Proportional Damper Control
- Airflow Control
- Humidity Control
- CO2 Control
- Electrical Pre-Heater
- Electrical After-Heater
- BacNET MSTP
- Weekly Timer
- Filter Contamination Info (DPS)
- OA Temperature Sensor
- RA Temperature Sensor
- SA Temperature Sensor
- SA Fan Control
- RA Fan Control
- On/Off Damper Control
- On/Off By-Pass Damper Control
- Compressor Control
- 4 Way Control
- Filter Contamination Info (Time)