EVER AC
EVER AC SERIES Units office, store, home etc. the fresh air in the ventilation applications of the environments does not have the heat load coming from the fresh air by providing them to be heated at the temperatures exhausted from the inner environment.
Descriptions
Features
Options
EVER AC SERIES Units office, store, home etc. the fresh air in the ventilation applications of the environments does not have the heat load coming from the fresh air by providing them to be heated at the temperatures exhausted from the inner environment.
Supply and Exhaust Air Fan (EVHR AC – EVER AC) – AC PLUG FAN
Backward curved plug fans are used in heat and energy recovery units. Fan blades have high aerodynamic efficient backward curved design. Plug fans are used for high efficiency and low sound levels. With AC Fans, maintenance costs are reduced as the fans are directly connected to the motors; the belt and pulley problems are eliminated.Supply and Exhaust Air Fan (EVHR AC EC – EVER AC EC) – EC PLUG FAN
The fans in heat and energy recovery units are equipped with innovative Electronically Commutated EC motor technology. EC motors have higher efficiency and simple speed control. Fan blades have high aerodynamic efficient backward curved design. EC motors
reduce the energy consumption and increase the energy efficiency of the unit. With EC Fans, maintenance costs are reduced as the fans are directly connected to the motors; the belt and pulley problems are eliminated.
Filter
To increase indoor air quality and to protect the equipments used in unit, ISO Course % 45 class filters (according to ISO 16890 standard) are used for both exhaust and supply air streams.Casing & Insulation
High corrosion resistive 200 gr/m² galvanize coated steel is used for the casing. Inside of outdoor air stream is insulated with 10 mm, outside of outdoor air stream is insulated with 5 mm; inside of indoor air stream is insulated with 10 mm non-flammable acoustics foam against sound and thermal conduction.Cellulosic Paper Type Crossflow Heat Exchanger (EVER AC)
EVER AC energy recovery ventilation units with heat pump have cellulosic crossflow, high efficient plate heat recovery exchangers. The exchanger transfers sensible heat and moisture between supply and exhaust air. Thus, it is also possible to transfer latent heat. With the optimization of heat exchanger, temperature and humidity efficiency is increased, pressure drop is decreased. Cellulosic paper type crossflow Heat Exchanger prevents decreasing moisture in winter time and increasing moisture in summer time.Control System
ENECON control unit is developed for controlling of heat recovery units’ equipments, meeting the demands coming from the customers and is user friendly designed. ENECON is capable of controlling the standard equipments and optional accessories. ENECON Control unit can perform the basic functions. Besides, the control unit can be switched on/off via BMS, gets fault signals and controls all the functions via ModBus. Alternative controllers are listed in “Control System” part.Compressor and Heat Pump Cycle
High efficiency, fully hermetic compressors are used in the heat/ energy recovery units with heat pump. Externally balanced thermostatic expansion valve is used in the unit. The system safety is ensured with low and high pressure pressurestats. The system can work in heating or cooling mode depending on the season selection on the control panel. The unit has an automatic free-cooling system which enables further savings in order to reduce operating costs.Evaporator & Condenser
Copper tube – aluminum fin type and high efficiency evaporator and condenser are used. At the entrance of the evaporator, refrigerant distributor is used for a uniform distribution. In order to keep the pressure drops on the air side reduced, the air speed of 2.7 m/sec or a lower value is selected for evaporator and condenser. There is a stainless steel drain pan under the evaporator and condenser.- Ceiling type, integrated DX module, heat recovery ventilation device
- Two series with 7 models and different heat recovery exchanges in flow rate range of 500-4,000 m3 / h
- EVER AC Series Cellulosic Heat Exchanger Cross Flow Heat Recovery
- Low energy consumptionl with Plug Fan
- Low noise leve
- Optional F class filter
- Advanced, integrated automation system,
- Mod-Bus / BacNet alternatives
- Plug & Play
- Package design on the evaporator condenser and compressor device, which does not require external unit.
- Hermetic scroll&rotary compressor
- Utilizing the heat recovery and the energy of the conditioned air exhausted from the interior with the integrated Dx module, it ensures that the fresh air taken from the outside is blown into the surrounding environment. (The fresh air will overcome the load.) At this time, the exhaust air is exhausted by passing through the condenser, so high COP values are provided.
- ODA Temperature Sensor
- ETA Temperature Sensor
- SUP Temperature Sensor
- SUP Fan Control
- ETA Fan Control
- Compressor Control
- 4 Way Control
- Modbus RTU
- Weekly Timer
- Filter Contamination Info (DPS)
- Optional EC fan alternative
- Optional duct type electric heater
- Optional channel type muffler
- On/Off Damper Control
- Proportional Damper Control
- Airflow Control
- Humidity Control
- CO2 Control
- On/Off Heating Coil
- Proportional Heating Coil
- On/Off Cooling Coil
- Proportional Cooling Coil
- Electrical Pre-Heater
- BacNET
- Web Browser (TCP/IP)