Supply and Exhaust Air Fans
The fans in heat recovery units are equipped with innovative Electronically Commutated EC motor technology. EC motors have higher efficiency and simple speed control. Fan blades have high aerodynamic efficient backward curved design. Using the EC motors reduce the energy consumption and increase the energy efficiency of the unit. With EC Fans, maintenance costs are reduced as the fans are directly connected to the motors; the belt and pulley problems are
eliminated.
Supply and Exhaust Air Filters
To increase indoor air quality and to protect the equipments used in unit, ISO ePM 1 >50-65%, &ISO ePM 10 >50% class filters (according to ISO 16890 standard) are used for supply and exhaust air streams, respectively. F9 class filters can be also used optionally outside the unit. ISO ePM 1 >80% class filters reduce the available static pressure of the unit for the nominal air flow rate.
Casing & Insulation (EVU-PD)
The unit’s casing is made up of double skinned high corrosion resistive 200 gr/m² galvanize coated steel. 50 mm thickness and 50kg/m³ density of Rockwool insulation between the walls is used for thermal and sound insulation.
By-pass
PROVENT units have by-pass ventilation as standard. During by-pass ventilation, no heat transfer occurs between exhaust and fresh air stream. In transition periods and at nights in summer, by-pass module helps to cool down (free-cooling) and heat up (free-heating) the building without any energy expense.
Heat Recovery Exchanger (Aluminum)
PROVENT heat recovery ventilation units have aluminum counterflow, high efficient plate heat recovery exchangers. Plate heat recovery exchangers have plates that are produced improved surface areas to provide high efficient and leakage free design. With the optimization of exchanger heat transfer is increased and pressure drop is decreased. Heat recovery exchanger has Eurovent certification.
Control System
ENECON PLUS control unit is developed for controlling of heat recovery units’ equipments, meeting the demands coming from the customers and is user-friendly designed. ENECON PLUS is capable of commanding the equipments in standard unit and optional accessories. ENECON PLUS Control unit can be performed the basic functions without any control panel, with Standard Panel can be also used more functional. Besides, the control unit can control the all functions via ModBus and switch on/off via BMS as optional. Alternatives different from ENECON PLUS controller are listed in “Control System” part.